Product Specification Book
Product Name: | Humidity sensor |
Product model: | SJL31SY |
Version: | V1.0 |
Formulator: | He Genwen |
Reviewer: | Yuan Chao |
This product is a resistive polymer humidity sensor (SJL31SY) ,It has the characteristics of high humidity resistance, fast response speed, low humidity hysteresis, stable and reliable performance, consistency and good interchangeability. The product characteristics are compatible with mainstream humidity sensors in the industry.
unit: mm(tolerance: ±0.5mm)
Application areas
Home appliance industry: air conditioning, humidification equipment, dehumidification equipment, air freshener and other electrical appliances;
Industrial and agricultural: atmospheric environment detection, industrial process control, measuring instruments, greenhouse planting, warehousing, food preservation, etc.
Gift industry: thermometer, electronic perpetual calendar, radio clock (RCC)、Digital photo frames, family weather stations, etc.;
model SJL31SY;
Product compliant ROHS、REACH Environmental protection requirements.
5.1、Working voltage, frequency
Operating voltage: Vpp≤5.5V/AC;
Operating frequency: 0.5 ~2k Hz;
5.2、Working temperature and humidity
Operating temperature: 0 ~50℃;
Working humidity: 20 ~95%RH;
5.3、Stability, temperature characteristics
stability: ≤2%RH/Year;
Temperature characteristics: ≤0.5%RH/℃;
5.4、Humidity detection accuracy
Measurement accuracy: ≤±3%RH;
5.5、Response speed
Response time: ≤20 Second
5.5、Water resistance
Soak in water for 10 minutes, and after natural drying and recovery, humidity changes ≤2% RH
Soak in water for 30 minutes, and after natural drying and recovery, humidity changes ≤5% RH
6.1、Temperature 25 ℃ (±1℃),Determination frequency 1 KHZ, Set the operating voltage to 1 V/AC (Sine wave );
6.2、The detection equipment is an AC bridge (LCR) (Note: No ordinary multimeter resistance test can be used );
6.3、Use constant temperature and humidity chamber equipment: CZ-A-150F。
Refer to Attachment 1
Standard test conditions: ambient temperature 25 ℃、Number of measurement frequency 1 kHz、 Measure voltage 1 V/AC (Sine wave ) As a benchmark.Characteristics measurement, put the humidity sensor into 25 before measurement ℃ /30%RH The humidity generator can be placed in the dry air for 30 minutes. RH, After 30 minutes, the impedance value was determined.
Test device: LCR Electric bridge (TH2810),Constant temperature and humidity test box, handheld ROTRONIC High-precision temperature and humidity meter (±1%RH)
Serial number | project | Test Methods | Standard value |
1 | Pin strength |
10N Pull pins in vertical shell direction for 10 seconds | No damage, pins fall off, normal electrical performance |
2 | Impact resistance |
On hard floor 1 m High, free fall 3 times | No damage, pins fall off, normal electrical performance |
3 | Vibration resistance | Frequency 10 ~55Hz、 Amplitude 1.5 mm (10~55~10Hz)Towards X-Y-Z direction Vibration for 2 hours respectively | No damage, pins fall off, normal electrical performance |
4 | Welding resistance | Immerse the sensor pins into a 350-degree tin tank. 5 Pick it up in seconds, repeat twice; | ±5%RH Within |
5 | cold resistance | Temperature -10 ℃Place the following air for 1000 hours | ±5%RH Within |
6 | Wet resistance | Temperature 50 ℃、Humidity 90% RH Place in the air for 1000 hours | ±5%RH Within |
7 |
Temperature cycle | -10℃Leave for 30 minutes, Heat up to 50 ℃/60%RH, Leave it for 30 minutes; 100 cycles |
±5%RH Within |
8 | Humidity cycling | 25℃,30%RH Leave for 30 minutes, transfer to 90% RH Leave for 30 minutes, cycle 100 times |
±5%RH Within |
9 | Solvent resistant | At room temperature, place the sensor in organic gas, alcohol and acetone air for 30 minutes. |
±5%RH Within |
10 | Powered-on-release | Normal indoor (Normal temperature and humidity ) 1kHz, 5Vpp Square wave, placed for 1000 hours in a row | ±5%RH Within |
11 | Water resistance | Soak in water for 30 minutes, dry and restore | ±5%RH Within |
Note: 1. The standard value is (25℃,60%RH) The impedance of the measured humidity varistor in the environment;
2. After each reliability test, the sensor is placed in normal temperature and humidity air, and then the humidity deviation corresponding to its impedance changes is measured.
9.1、The sensor without a shell is placed flat in the blister box, and a layer of blister box contains 50 sensors;
9.2、20 The layered blister box is stacked together, and a vamp box is placed on the top instead of the lid to prevent the sensor from falling;
9.3、Single-sided glue is wound and fixed, and put into a paper tray;Carton size (mm):L190*W150*H55, There are 1000 sensors in total;
9.4、Choose carton packaging of different sizes according to the order quantity;
9.5、The sensor with a shell is bagged;
License Agreement
The above content is provided by Shenzhen Yuanjian Sensing Technology Co., Ltd., and all rights reserved. Without the written permission of the company, any paragraphs and chapter content in this manual shall not be excerpted, copied or copied or disseminated in any form. Otherwise, all consequences shall be borne by the violators, and the company reserves all legal rights.
The Company reserves the right to modify the product specifications described in the manual without prior notice.
warn
Use and personal injury
Do not use this product on safety protection devices or emergency stop devices, and in any application that may cause personal injury due to failure of this product;Before using this product, please read the contents of this instruction manual carefully;
No use near flammable gases
It is prohibited to use in places with flammable and explosive gases;
Direct contact and sensors are strictly prohibited
To prevent contamination of the wet-sensitive film, avoid fingers from touching the surface of the component;Sweat can contaminate the wet film and cause performance drift. Please wear anti-static finger covers when contacting the sensor;Avoid chemical reactions
Avoid using in environments containing the following gases: salt, sulfur dioxide, halogen gas, ammonia, alcohol, glycol ethers, aldehydes, etc.;
Working environment
Recommended temperature range -10 ℃-60℃ ,Humidity range 0-100% RH。 Exceeding the recommended range may result in temporary drift of measurement results;This product is not sensitive to light, but is exposed to sunlight or ultraviolet radiation for a long time, which will also accelerate aging;
Three guarantee service
Under normal environmental conditions, this product promises three guarantee services within 1 year.
0℃ | 5℃ | 10℃ | 15℃ | 20℃ | 25℃ | 30℃ | 35℃ | 40℃ | 45℃ | 50℃ | 55℃ | |
10%RH | 75142 | 68451 | 61200 | 53124 | 45124 | 39512 | 33154 | 29481 | 25412 | 21452 | 17854 | 15475 |
15%RH | 51242 | 43214 | 38412 | 30124 | 24123 | 20145 | 16458 | 13452 | 11012 | 9845 | 8147 | 6548 |
20%RH | 25704 | 20650 | 18240 | 14238 | 11000 | 8700 | 7238 | 5842 | 4899 | 4055 | 3226 | 2630 |
25%RH | 12589 | 9683 | 7514 | 6310 | 4615 | 3565 | 2954 | 2432 | 2000 | 1545 | 1212 | 933 |
30%RH | 6180 | 4688 | 3580 | 2880 | 2065 | 1530 | 1232 | 972.7 | 769.4 | 585.3 | 436.1 | 327.5 |
35%RH | 3048 | 2249 | 1587 | 1288 | 952.0 | 691.8 | 555.9 | 420.7 | 325.1 | 248.9 | 187.5 | 140.6 |
40%RH | 1503 | 1132 | 798.0 | 621.7 | 442.6 | 316.2 | 249.8 | 185.4 | 141.9 | 107.6 | 82.8 | 62.2 |
45%RH | 781.6 | 578.1 | 384.6 | 295.1 | 210.0 | 147.91 | 116.95 | 90.99 | 71.78 | 55.21 | 41.59 | 31.48 |
50%RH | 400.9 | 302.1 | 201.8 | 151.9 | 105.0 | 78.88 | 60.36 | 47.32 | 36.60 | 29.99 | 23.81 | 17.34 |
55%RH | 210.0 | 155.2 | 108.6 | 81.28 | 57.94 | 43.65 | 33.19 | 25.70 | 20.42 | 16.67 | 13.09 | 10.47 |
60%RH | 113.9 | 87.24 | 61.40 | 44.80 | 33.34 | 25.06 | 18.80 | 15.35 | 12.23 | 10.15 | 8.24 | 6.73 |
65%RH | 64.71 | 48.75 | 34.20 | 25.70 | 19.41 | 14.69 | 11.40 | 9.59 | 7.87 | 6.64 | 5.48 | 4.67 |
70%RH | 36.81 | 28.40 | 20.63 | 15.36 | 11.61 | 9.31 | 7.51 | 6.21 | 5.32 | 4.59 | 4.03 | 3.55 |
75%RH | 20.94 | 16.22 | 12.00 | 9.33 | 7.28 | 5.85 | 5.00 | 4.26 | 3.74 | 3.37 | 3.00 | 2.69 |
80%RH | 12.66 | 10.00 | 7.58 | 6.25 | 5.05 | 4.18 | 3.60 | 3.25 | 2.91 | 2.68 | 2.42 | 2.23 |
85%RH | 7.98 | 6.38 | 5.00 | 4.27 | 3.61 | 3.09 | 2.74 | 2.50 | 2.30 | 2.13 | 2.00 | 1.86 |
90%RH | 5.06 | 4.25 | 3.66 | 3.19 | 2.83 | 2.58 | 2.34 | 2.15 | 2.01 | 1.88 | 1.75 | 1.67 |
95%RH | 3.80 | 3.50 | 3.20 | 3.00 | 2.58 | 2.34 | 2.10 | 2.00 | 1.80 | 1.70 | 1.60 | 1.50 |
Attachment 1: SJL31SY Temperature and humidity characteristic impedance table