  • Multi-parameter atmospheric environment online detector

  • Test indoor environment and public open areas PM2.5 Particle concentration;At the same time, it can be used to detect the temperature, humidity, air pressure of the environment, VOC 、CO2 、O2 、 Many other parameters such as formaldehyde or carbon monoxide are very powerful.


Product Manual

Product Specification Book

  • Product Name:

    Multi-parameter atmospheric environment online detector

    Product model:

    INSXX-S-P

    Version:

    V1.0

    Formulator:

    He Genwen

    Reviewer:

    Yuan Chao

     

    Version

    Change content

    Change people

    Change date

    V1.0

    New

    He Genwen

    2020-4-24

     

    Uses of instruments

    Test indoor environment and public open areas  PM2.5  Particle concentration;At the same time, it can be used to detect the temperature, humidity, air pressure of the environment, VOC 、CO2 、O2 、  Many other parameters such as formaldehyde or carbon monoxide are very powerful.

    Main working parameters of comprehensive air quality detector:

    Operating temperature range

    -10 ~ 50℃

    Working humidity range

    0 ~ 95%RH

    Storage temperature range

    -20 ~ 60℃

    Power input

    DC 12~24V

    Current consumption

    The average is 350 mA, Peak value is 600 mA

    Signal output

    Modbus RS485,9600bps,1  Start bits, 8 data bits, 1 stop bit, no check bit (Optional wifi,ZIGBEE,TCP/IP,lorawan)

    size

    450g/133mm×133mm×39mm

     

    Comprehensive air quality detector detection capability and detection range

    (*Customers can choose different parameter combinations according to their own use requirements ):

    Main detection parameters

    Detection range

    Detection accuracy

    Testing methods, etc.

    PM2.5  Particle concentration measurement

    0~500µg/m3

    ﹤ ±15µg/m3+10%reading

    Laser scattering method

    PM10  Particle concentration measurement

    0~500µg/m3

    ﹤ ±15µg/m3+10%reading

    Laser scattering method

    Formaldehyde gas

    0~2.00ppm;

    ﹤ ±5% FS

    Electrochemistry

    CO  gas

    0~500ppm;

    ﹤ ±5% FS

    Electrochemistry

    Volatile odor detection

    (VOC  gas )

    0~100ppm

    ﹤ ±20%

    semiconductor

    Flammable

    0~100%lel

    ﹤ ±10% FS

    semiconductor

    Oxygen concentration monitoring

    0~25.0%VOL

    ﹤ 2%FS

    Electrochemistry

    CO2  Test

    400~5000ppm

    ±75ppm±5%reading

    Infrared non-dispersed absorption  (NDIR)

    Temperature measurement

    -20 ~ 85℃

    ±0.5℃

    Capacitive

    Humidity measurement

    0 ~ 100%RH

    ±3%RH

    Capacitive

    Atmospheric pressure

    200~1200hPa

    ±0.1%

    MEMS

    Scalable  (NO/O3/NO2/NO/SO2/H2S/NH3/VOC/PH3/CL2/HCL/HCN/HF)Isoelectrochemical principle sensors, select up to 4, and the parameters are based on the selected parameters.

    Depends on the number

     

    Installation and wiring

      Do not connect the transmitter to a voltage above 24 VDC  place.

      Refer to the product appearance and dimension drawings for installation equipment in Figure 1.

      Install the transmitter in a position where it needs to be detected, and should be kept away from the heating element or the source of steam to prevent direct sunlight.    When wiring the circuit, connect the wires to the terminals to ensure that the wiring is correct and firm.

     

    Product size diagram  (unit: mm)

     

    Wiring instructions:

    Interface description:

    From right to left, numbered as 1-7 in sequence, defined as follows:

    1、+12V;  2、GND;  3、RS485A;  4、RS485B;5、I1/V1;6、I2/V2;7、TCP/IP

     

    Communication Agreement Section:

    use  MODBUS  The agreement RTU  Way, in RTU  In mode, use RTU  In mode, message sending must start at least 3.5 character pause intervals.When the first domain (Address Domain ) Received, each device decodes to determine whether it is sent to its own.After the last character transmission, a pause of at least 3.5 characters time calibrates the end of the message.A new message can be stopped here and started.The entire message frame must be transmitted as a continuous stream.If there is a pause of more than 3.5 characters before the message frame is completed, the receiving device refreshes the incomplete message and assumes that the next byte is the address field of a new message.

     

    1 、    Hardware adoption  RS485 , Master-slave half-duplex communication, host call slave address, slave reply mode communication.

    2 、    Data frame format: 1 start bit, 8 data bits, 1 stop bit, no check bit.

    3 、    Baud rate: 9600 bps。

    4 、    Message frames include: address field, function code field, data field, CRC16  Detection domain.

    5 、     This device supports hexadecimal 03 H 、06H  Function code (That is, decimal 03 and 06 function codes ) 。Of which 03 H  Used to read the device stack, 06 H  Used to modify the device stack.

     

    The corresponding stack of equipment is planned as follows:

    Register address

    Corresponding parameters

    Decimal point

    unit

    Data description

    40001

    CO2

    0

    ppm


    40002

    PM2.5

    0

    ug/m3


    40003

    O2

    1

    VOL%


    40004

    VOC

    2

    ppm


    40005

    SMOKE

    0

    ppm


    40006

    temperature

    1



    40007

    humidity

    1



    40008

    Atmospheric pressure

    1

    hPa  (Happa )


    40009

    formaldehyde

    2

    ppm


    40010

    Carbon monoxide

    0

    ppm


    40011

    illumination

    0

    lux


    40012

    CH4

    0

    ppm


    40013

    noise

    1

    db


    40014

    PM10

    0

    ug/m3


    40015





    40016

    Device address

    0


    Default is 1

    40017

    Baud rate

    0


    Default 9600

     

     

    Notes on using:

    (1)  RS485  Communication cables need to be shielded twisted pair cables, and if necessary, 2 250 ΩTerminal matching resistor.

    (2)  The use environment should be free of conductive dust, corrosion-free metals and gases that destroy insulation, and avoid direct light and rain.

    (3)  More than 90% for a long time RH  Working in a high humidity environment will cause drift.

    (4)  Avoid placing components in salt spray, acidic or oxidized gases  (Sulfur dioxide, hydrochloric acid, etc. ) In the environment.

    After-sales service and warranty terms:

    1、Customers can enjoy a 1-year warranty from the date of purchase.                                      

    2、The validity period of the warranty starts from the date of issuance of the invoice or the date of registration and purchase of the warranty card, and online sales start on the date of signing. 

    3、When requesting after-sales service, please contact the relevant person in charge to send it back to the company's after-sales service department.

     

    Note: After-sales service does not include the following situations:

    1、Failures caused by unauthorized disassembly and assembly, modification and modification of products;

    2、Failures caused by falling during use and handling;

    3、The label on the fuselage must be kept intact and tear it without permission will not be guaranteed;

    4、Product failure caused by failure to meet the use environment of this product;

    5、This product is burned and damaged due to wiring or power supply errors.


  • Home
  • Product Display
  • Qualification certificate
  • Application News
  • Consulting
  • phone:0755-26588758 13714285279(倪先生) 13922884770(王先生) 13923716479(倪先生)


    fax:0755-26747274


    email:info@source-sensor.com


    address:East 3rd Floor, Building 15, Majialong Industrial Zone, Nantou Street, Nanshan District, Shenzhen


    Copyright©2002-2023 Yuanjian Sensing Technology. All Rights Reserved Copyright 粤ICP备17008245号-5 技术支持:图页网 网站地图xml 网站地图html