Product Manual
Product Specification Book
Product Name: | Multi-parameter atmospheric environment online detector |
Product model: | INSXX-S-P |
Version: | V1.0 |
Formulator: | He Genwen |
Reviewer: | Yuan Chao |
Version | Change content | Change people | Change date |
V1.0 | New | He Genwen | 2020-4-24 |
Test indoor environment and public open areas PM2.5 Particle concentration;At the same time, it can be used to detect the temperature, humidity, air pressure of the environment, VOC 、CO2 、O2 、 Many other parameters such as formaldehyde or carbon monoxide are very powerful.
Main working parameters of comprehensive air quality detector:
Operating temperature range | -10 ~ 50℃ |
Working humidity range | 0 ~ 95%RH |
Storage temperature range | -20 ~ 60℃ |
Power input | DC 12~24V |
Current consumption | The average is 350 mA, Peak value is 600 mA |
Signal output | Modbus RS485,9600bps,1 Start bits, 8 data bits, 1 stop bit, no check bit (Optional wifi,ZIGBEE,TCP/IP,lorawan) |
size | 450g/133mm×133mm×39mm |
Comprehensive air quality detector detection capability and detection range
(*Customers can choose different parameter combinations according to their own use requirements ):
Main detection parameters | Detection range | Detection accuracy | Testing methods, etc. |
PM2.5 Particle concentration measurement | 0~500µg/m3 | ﹤ ±15µg/m3+10%reading | Laser scattering method |
PM10 Particle concentration measurement | 0~500µg/m3 | ﹤ ±15µg/m3+10%reading | Laser scattering method |
Formaldehyde gas | 0~2.00ppm; | ﹤ ±5% FS | Electrochemistry |
CO gas | 0~500ppm; | ﹤ ±5% FS | Electrochemistry |
Volatile odor detection (VOC gas ) | 0~100ppm | ﹤ ±20% | semiconductor |
Flammable | 0~100%lel | ﹤ ±10% FS | semiconductor |
Oxygen concentration monitoring | 0~25.0%VOL | ﹤ 2%FS | Electrochemistry |
CO2 Test | 400~5000ppm | ±75ppm±5%reading | Infrared non-dispersed absorption (NDIR) |
Temperature measurement | -20 ~ 85℃ | ±0.5℃ | Capacitive |
Humidity measurement | 0 ~ 100%RH | ±3%RH | Capacitive |
Atmospheric pressure | 200~1200hPa | ±0.1% | MEMS |
Scalable (NO/O3/NO2/NO/SO2/H2S/NH3/VOC/PH3/CL2/HCL/HCN/HF)Isoelectrochemical principle sensors, select up to 4, and the parameters are based on the selected parameters. Depends on the number |
Do not connect the transmitter to a voltage above 24 VDC place.
Refer to the product appearance and dimension drawings for installation equipment in Figure 1.
Install the transmitter in a position where it needs to be detected, and should be kept away from the heating element or the source of steam to prevent direct sunlight.
When wiring the circuit, connect the wires to the terminals to ensure that the wiring is correct and firm.
Interface description:
From right to left, numbered as 1-7 in sequence, defined as follows:
1、+12V; 2、GND; 3、RS485A; 4、RS485B;5、I1/V1;6、I2/V2;7、TCP/IP
Communication Agreement Section:
use MODBUS The agreement RTU Way, in RTU In mode, use RTU In mode, message sending must start at least 3.5 character pause intervals.When the first domain (Address Domain ) Received, each device decodes to determine whether it is sent to its own.After the last character transmission, a pause of at least 3.5 characters time calibrates the end of the message.A new message can be stopped here and started.The entire message frame must be transmitted as a continuous stream.If there is a pause of more than 3.5 characters before the message frame is completed, the receiving device refreshes the incomplete message and assumes that the next byte is the address field of a new message.
1 、 Hardware adoption RS485 , Master-slave half-duplex communication, host call slave address, slave reply mode communication.
2 、 Data frame format: 1 start bit, 8 data bits, 1 stop bit, no check bit.
3 、 Baud rate: 9600 bps。
4 、 Message frames include: address field, function code field, data field, CRC16 Detection domain.
5 、 This device supports hexadecimal 03 H 、06H Function code (That is, decimal 03 and 06 function codes ) 。Of which 03 H Used to read the device stack, 06 H Used to modify the device stack.
Register address | Corresponding parameters | Decimal point | unit | Data description |
40001 | CO2 | 0 | ppm | |
40002 | PM2.5 | 0 | ug/m3 | |
40003 | O2 | 1 | VOL% | |
40004 | VOC | 2 | ppm | |
40005 | SMOKE | 0 | ppm | |
40006 | temperature | 1 | ||
40007 | humidity | 1 | ||
40008 | Atmospheric pressure | 1 | hPa (Happa ) | |
40009 | formaldehyde | 2 | ppm | |
40010 | Carbon monoxide | 0 | ppm | |
40011 | illumination | 0 | lux | |
40012 | CH4 | 0 | ppm | |
40013 | noise | 1 | db | |
40014 | PM10 | 0 | ug/m3 | |
40015 | ||||
40016 | Device address | 0 | Default is 1 |
40017 | Baud rate | 0 | Default 9600 |
(1) RS485 Communication cables need to be shielded twisted pair cables, and if necessary, 2 250 ΩTerminal matching resistor.
(2) The use environment should be free of conductive dust, corrosion-free metals and gases that destroy insulation, and avoid direct light and rain.
(3) More than 90% for a long time RH Working in a high humidity environment will cause drift.
(4) Avoid placing components in salt spray, acidic or oxidized gases (Sulfur dioxide, hydrochloric acid, etc. ) In the environment.
After-sales service and warranty terms:
1、Customers can enjoy a 1-year warranty from the date of purchase.
2、The validity period of the warranty starts from the date of issuance of the invoice or the date of registration and purchase of the warranty card, and online sales start on the date of signing.
3、When requesting after-sales service, please contact the relevant person in charge to send it back to the company's after-sales service department.
1、Failures caused by unauthorized disassembly and assembly, modification and modification of products;
2、Failures caused by falling during use and handling;
3、The label on the fuselage must be kept intact and tear it without permission will not be guaranteed;
4、Product failure caused by failure to meet the use environment of this product;
5、This product is burned and damaged due to wiring or power supply errors.
phone:0755-26588758 13714285279(倪先生) 13922884770(王先生) 13923716479(倪先生)
fax:0755-26747274
email:info@source-sensor.com
address:East 3rd Floor, Building 15, Majialong Industrial Zone, Nantou Street, Nanshan District, Shenzhen
Copyright©2002-2023 Yuanjian Sensing Technology. All Rights Reserved Copyright 粤ICP备17008245号-5 技术支持:图页网 网站地图xml 网站地图html