  • Micro pressure differential transmitter BPS-12A

  • The working principle of the micro-pressure differential transmitter is that the pressure of the medium acts directly on the sensor's diaphragm, causing the diaphragm to produce a micro-displacement proportional to the pressure of the medium, causing the sensor's resistance to change, and use electronic circuits to detect this change, and convert and output a standard signal corresponding to this pressure.

Product Manual

pic

Product Specification Book

  • 1. Product Introduction

    The working principle of the micro-pressure differential transmitter is that the pressure of the medium acts directly on the sensor's diaphragm, causing the diaphragm to produce a micro-displacement proportional to the pressure of the medium, causing the sensor's resistance to change, and use electronic circuits to detect this change, and convert and output a standard signal corresponding to this pressure.

    This product uses imported integrated chips, with wide voltage power supply, strong anti-interference ability, reverse connection protection, high accuracy, good stability, and can artificially correct zero points.

    The micro-pressure differential transmitter obtains the pressure difference between air and non-corrosive gas, and is suitable for various industrial automatic control environment fields such as HVAC, dust-free clean workshop, pipeline air supply, boiler negative pressure, oven boosting, ventilation equipment, fan control, variable air volume system, etc.

     

    2. Product device introduction

     

    3. Model and description

    4. Wiring method

     

    V. Product Features

    1. Linear pressure characteristics and selectable pressure measurement range

    2. Working voltage: 16-30 VDC

    3. Signal output: 4-20 mA / 0-5V / 0-10V/RS485  type

    4. Zero adjustment

    5. Simple and quick installation by integrated brackets inside the housing

    6. Calibration and temperature compensation measurement signals

     

    6. Application areas:

    1. Measure subtle pressure difference in ventilation equipment and air conditioning ducts

    2. Check air flow

    3. Monitor filters and control fans

     

    7. Model summary

    unit: Pa

    Product Series

    Product Name

    Pressure range measurement

    Measurement range 1

    Measurement range 2

    Measurement range 3

    Measurement range 4

    Overload pressure

    Shock pressure

    BPS-01

    100Pa  Micro pressure differential transmitter

    ±50Pa

     

    -

    ±65Pa

    ±100Pa

    ±10Kpa

    ±20Kpa

    BPS-02

    1KPa  Micro pressure differential transmitter

    ±250Pa

     

    -

    ±500Pa

    ±1Kpa

    ±10Kpa

    ±20Kpa

    BPS-03

    10KPa  Micro pressure differential transmitter

    ±2KPa

    ±3KPa

    ±5KPa

    ±10KPa

    ±85Kpa

    ±110Kpa

    BPS-04

    35Kpa  Micro pressure differential transmitter

    ±30KPa

    ±35KPa

     

    -

     

    -

    ±175Kpa

    ±280Kpa

     

    8. Operation mode

    The sensor obtains the pressure difference value through the silicon piezoresistive element, which forms a linear 4-20 through the sensed deviation value. mA/0-5V/0-10V/RS485  Type Temperature compensation output signal.

     

    9. Mechanical Design

    A micro pressure differential transmitter consists of the following:

    1. Sensor housing fixing bracket, cable entry, movable buckle cover with safety screws

    2. Silicon piezoresistive components are used for force measurement

    3. Including terminals and for selecting measurement range  DIP  Printed circuit board for switches ( “See Debugging Precautions” )

    4. Zero adjustment button  ( “See Debugging Precautions” )

     

    10. Precautions for debugging

    Adjustable measurement range: pressure range and direction, adjustable through dial switch

    Zero adjustment: clear and calibration

    Open the panel short button (1Within seconds )The zero point adjustment button can be cleared.

    (Please manually clear the zero while keeping it parallel to the installation method; please manually clear the zero while the positive and negative air intake ports are connected. )

     

    Operation steps

    state

    result

    button

    1. PCB Power on

    2. Keep the pressure difference between positive and negative pressure air inlets at zero

    3. Click 0 Click the key

     

     

    The red light is on

     

     

    0 Point calibration

     

     

    11. Technical parameters

    Product data:

    Measurement range

    Reference "Model Summary"

    Sensing elements

    Silicon piezoresistive components

    Room temperature

    20-25℃ ,Measurement during correct installation  (FS=Full range measurement )

    Accuracy: Total error

    Temperature offset

    ± 1 % /± 0.5 % / ±0.2% FS

    <±0.1% FS /°C

    medium

    Air and non-corrosive gases

    Permissible medium temperature range

    -20-85℃

    maintain

    Long-term stability

    Electrical characteristics:

     

     

    All output types

    power supply

    Safe and ultra-low voltage

    Voltage

    Power consumption

    DC16-30V

    <1.5 VA

     

     

     

    4-20mA  Output Type

    Output current

    4-20 mA

    load

    ≤250 Ω

    Output

    Non-electrical separation, polarity-free two-wire connection, rectifier bridge anti-reverse connection

    Link:

    Electrical connection

    Screw terminal

    Maximum 1.5 mm²cable

    cable

    Cable sealing gland port  (No resistance to cable deformation )

    Pressure connection

    Pressure nozzle, 6.21  mm  diameter

     

    Environmental conditions:

    Permissible ambient temperature

    run

    -20-85℃

    transportation / store

    -40-125 ℃

    Permissible ambient humidity

    <90 % rh (No condensation )

     

    12. Appearance size (long *Width *High: 99.0 *101.5*39.9mm, tolerance: ±1mm)

     

    13. Installation method

     

    First use the back ruler to mark the installation hole position on the wall, and the drilling depth is 30 mm  of Ø6mm  Place the expansion tube on the wall hole, then open the snap of the micro-pressure differential transmitter and turn on the cover

    Cover, tap the screws  (ST3.5×25) Fix the designated seat on the wall through the fixing hole of the micro-voltage differential transmitter, connect the inlet and outlet wires through the waterproof connector, and finally cover the cover.

    Notice:

    No air duct connection device is provided during supply;

    Please read the instructions carefully and follow the wiring diagram. If the product is damaged due to wiring, it cannot be warranted.


  • Home
  • Product Display
  • Qualification certificate
  • Application News